Outcome | Tool | Unit |
---|---|---|
Primary Endpoints | ||
  Maximum knee extension strength | Maximum and relative isometric knee extension strenght in seated leg extension machine (Edition-Line, gym80, Gelsenkirchen, Germany) with force transducer (mechaTronic, Hamm, Germany) | [N] and [N/kg] |
  Reactive balance performance, eyes open | Postural sway upon perturbation on two-dimensional platform (Posturomed, Haider Bioswing, Pullenreuther, Germany) with acceleration sensor (MicroSwing®6, Haider Bioswing, Pullenreuth, Germany) | [mm] |
  Dual task gait speed | 8m habitual gait speed while counting backwards in steps of three, measured with photoelectric time gates (DLS/F03, Sportronic, Leutenbach-Nellmersbach, Germany) | [m/s] |
  Agilitya | Total and split times of the ACE measured with photoelectric time gates (DLS/F03, Sportronic, Leutenbach-Nellmersbach, Germany) | [s] |
Secondary Endpoints | ||
 Neuromuscular | ||
  Maximum leg curl strength | Maximum and relative isometric leg curls strenght in prone leg curl machine (Edition-Line, gym80, Gelsenkirchen, Germany) with force transducer (mechaTronic, Hamm, Germany) | [N] and [N/kg] |
  Maximum handgrip strength | Maximum and relative isometric hangrip strength in standing upright position measured with hand dynamometer (Digimax, Hamm, Germany) with force transducer (mechaTronic, Hamm, Germany) | [N] and [N/kg] |
  Explosive strength of lower extremeties | CMJ height on force plate (FP4060-15 Bertec, Columbus, OH, USA) | [m] |
  Reactive balance performance, eyes closed | Postural sway upon perturbation on two-dimensional platform (Posturomed, Haider Bioswing, Pullenreuther, Germany) with acceleration sensor (MicroSwing®6, Haider Bioswing, Pullenreuth, Germany) | [mm] |
  Static balance performance, higher support | Total sway of the COP in tandem stance on force plate (FP4060-15 Bertec, Columbus, OH, USA) | [m] |
  Static balance performance, lower support | Total sway of the center of pressure in one-legged stance (COP) on force plate (FP4060-15 Bertec, Columbus, OH, USA) | [m] |
  Gait speed | 8m habitual gait speed measured with photoelectric time gates (DLS/F03, Sportronic, Leutenbach-Nellmersbach, Germany) | [m/s] |
  Triple task gait speed | 8m habitual gait speed while counting backwards in steps of three and simultaneously carrying a glass filled with water (to ¾), measured with photoelectric time gates (DLS/F03, Sportronic, Leutenbach-Nellmersbach, Germany) | [m/s] |
 Cardiovasular | ||
  Aerobic capacitya | VO2max(rel) (Cortex Metamax, Leipzig, Germany) during spiroergometric test on a cycle ergometer (Ergoline, Bitz, Germany) | [ml/min/kg] |
 Cognitiv | ||
  Inhibitory controla | Eriksen-Flanker task accuracy (congruent and incongruent trials) and reaction time (congruent and incongruent trials) | [% correct] and [ms] |
  Working memorya | N-back task Hit rate and reaction time (target and non-target) | [% correct targets/error rate] and [ms] |